Collect pairs of points for coordinate system adjustment.
Select first the points in Old system. Then scroll back to first pair (|<) and select the points in New system. When Auto is On, next point is asked automatically. The minimum number of pairs is four.
Notice that points in old system must have point numbers and same point number may exist only once.
The current coordinates of the points. When selecting old points, this radiobutton must be on.
The new coordinates of the points. When selecting old points, this radiobutton must be on.
Input default accuracy for the points. You can change the values manually or use Set-button to set all three values (XYZ). Button with the Shift-key sets value for all points in the list.
Sets accuracy for point active in the dialog. With the Shift-key sets accuracy for all points.
You can remove point from calculation. Point will be shown in the list, but it's not used in calculation.
Ask next point automatically, when point is selected using mouse.
You can move to next/previous point or to start/end of the list.
Selecting points automatically from the active file by using point numbers (T4). You can select the old points using mouse and fetch the new points automatically. Be sure to set active file before fetching and select right column Old/New).
Shift+Fetch will find both old and new points. The old points are selected from the active vector file and the new points from the other file.
Removes point from the list.
Removes all points from the list.
There are some special settings related to this function.
Default values for the Accuracy-list.